The Priming feature must be disabled on the Madimack Pump prior to connecting the remote control wiring.
Navigating the Configuration Menu to Disable Priming
With the pump in OFF Mode, press and hold the Up and Down buttons simultaneously for 3 seconds to enter the parameter configuration menu.
Press the LOCK button repeatedly until Parameter 5 is displayed.
Use the Up or Down button to change the value to 0.
Wait 10 seconds without pressing any buttons. The setting will automatically save and the pump will exit the configuration menu.

Connections
Madimack Inverflow Eco and Inverflow Plus pumps may be connected to the Attendant using the communication cable provided with the pump. The communication cable must be attached to the drive using the connector slot as pictured below:
Connect the Green wire from the pump communication cable to the D+ pin on the Attendant Bus Port
Connect the Brown wire from the pump communication cable to the D- pin on the Attendant Bus port

Configuration Parameters