Connections
Madimack Inverflow Eco and Inverflow Plus pumps may be connected to the Attendant using the communication cable provided with the pump. The communication cable must be attached to the drive using the connector slot as pictured below:

Connect the Green wire from the pump communication cable to the D+ pin on the Attendant Bus Port
Connect the Brown wire from the pump communication cable to the D- pin on the Attendant Bus port

Configuration
Screen/Menu Navigation

Navigating the Configuration Menu
Press and hold the Up and Down buttons together for 3 seconds to enter parameter configuration mode.
Press and hold the Up and Down buttons together for 3 seconds to move to the next parameter.
Leave the pump for 10 seconds to save and exit parameter setting mode
Disable Priming
Poolside recommend that the default priming mode of the pump is disabled and priming is configured directly in the Attendant configuration. To do this please follow the procedure below:
Press and hold the Up and Down buttons together for 3 seconds to enter parameter configuration mode.
You will see the screen show parameter 1. Continue to press and hold the Up and Down buttons together for 3 seconds to move to the next parameter. Until you get to parameter 5.
Use the Up or Down buttons to set the value to 0.
Configuration Parameters