Ports to connect to on The Attendant: Bus 1 – 4
The Jandy AquaPure requires voltage to be supplied in order to communicate. Please reference the following diagram to connect the AquaPure to The Attendant.
Salt cell wiring diagram with 14v supplied via bus connection:

NOTE
Only one AquaPure/TruClear salt chlorine generator is supported per Bus port.
WARNING
Some Pro Series TruClear systems do not come with a port to connect to a pool automation. These systems can only be set up to run as a generic salt water generator with basic on/off control from a relay.
TruClear systems do not measure or display the actual salt level in the pool water. Instead, they are programmed to consistently show a default reading of 3000 ppm, regardless of the true salt concentration. Because of this limitation, it is essential to manually test the water’s salt levels using a reliable testing method, as recommended by the manufacturer.